METROBRICK Exceeds PCI Standard For Thin Brick
Not All Thin Brick Meets this rigorous standard. Click to see what sets METROBRICK® Apart.

Metropolitan Ceramics Thin Brick METROBRICK® shall be of standard grade quality and shall exceed all of the requirements of ASTM (American Society for Testing and Materials) C-1088, the standard specifications for thin veneer brick units made from clay or shale.

The ASTM C-1088 standard specifications also require the ASTM C-67 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile as shown to the right:

Download Test Results


Specification Test Standard METROBRICK®
Efflorescence ASTM C-67 None None
Chipping ASTM C-1088 Max. 3% < 2%
Size ASTM C-1088 TBX Grade Meets the Standard
Warpage ASTM C-1088 TBX Grade Meets the Standard
Modulus of Rupture ASTM C-67 250 lbs./sq. in. > 500 lbs. / sq. in.
Compressive Strength ASTM C-67 8,000 lbs./sq. in. Meets the Standard
Out of Square ASTM C-67 Plus or Minus 1/16 in Meets the Standard
Absorption ASTM C-67 Max. 5% < 3%
Saturation Coefficient ASTM C-1088 N/A N/A
Freeze - Thaw ASTM C-67 Min. 50 Cycles Passed 3,000 Cycles

Freeze-Thaw
Brick in Concrete

ASTM C-666 Procedure B
(as modified per PCI specification published April, 2007)
150 psi or greater Passed 300 cycles
Meets the Standard
Shear Bond Strength
to Portland Cement
ASTM C-482 Min. 50 psi > 150 psi
Chemical Resistance ASTM C-650 Not Affected Not Affected by tested chemicals

“METROBRICK®” will exceed ASTM C-1088 (Type TBX Select) requirements for exterior grade.