Metropolitan Ceramics Thin Brick “METRO®BRICK” shall be of standard grade quality and shall exceed all of the requirements of ASTM (American Society for Testing and Materials) C-1088, the standard specifications for thin veneer brick units made from clay or shale. The ASTM C-1088 standard specifications also require the ASTM C-67 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile as shown below:
|
| Specification |
Test |
Standard |
METRO®BRICK |
| Saturation Coefficient |
ASTM C-1088 |
N/A |
N/A |
| Efflorescence |
ASTM C-67 |
None |
Not Effloresced |
| Chipping |
ASTM C-1088 |
Max. 3% |
< 2% |
| Size |
ASTM C-1088 |
TBX Grade |
Exceeds the Standard |
| Warpage |
ASTM C-1088 |
TBX Grade |
Exceeds the Standard |
| Modulus of Rupture |
ASTM C-67 |
250 lbs./sq. in. |
> 500 lbs. / sq. in. |
| Compressive Strength |
ASTM C-67 |
8,000 lbs./sq. in. |
10,000 lbs./sq. in. |
| Absorption |
ASTM C-67 |
Max. 5% |
< 3% |
| Freeze - Thaw |
ASTM C-67 |
Min. 50 Cycles |
Passed 3,000 Cycles |
Shear Bond Strength
to Portland Cement |
ASTM C-482 |
Min. 50 psi |
> 150 psi |
| Chemical Resistance |
ASTM C-650 |
Not Affected |
Not Affected |
“METRO®BRICK” will exceed ASTM C-1088 (Type TBX Select) requirements for exterior grade.